Overview of resonance test equipment:
When calibrating a capacitive voltage transformer (CVT), the test frequency must be conducted at 50Hz. Meanwhile, the geographical conditions of the site are complex. Traditional experimental equipment is no longer sufficient to meet the requirements of on-site handling and testing.
Advantages of series resonant power supply in power system applications:
1. The required power capacity is greatly reduced. The series resonant power supply generates high voltage and high current through the resonance of the resonant reactor and the tested capacitor. In the entire system, the power supply only needs to provide the active part of the system. Therefore, the power required for testing is only the testing capacity. 1/Q.
2. The weight and volume of the equipment have been greatly reduced. In a series resonant power supply, not only is the bulky high-power regulator and ordinary high-power power frequency test transformer eliminated, but the resonant excitation power supply only requires 1/Q of the test capacity, greatly reducing the weight and volume of the system. 1/5-1/10 of regular testing equipment.
3. Improve the output voltage waveform. The resonant power supply is a resonant filtering circuit that can improve the waveform distortion of the output voltage, obtain a good sine waveform, and effectively prevent the test sample from being mistakenly broken down by harmonic peaks.
4. Prevent large short-circuit current fault points. In the series resonance state, when the weak insulation point of the tested product is broken down, the circuit immediately loses resonance, and the loop current quickly drops to 1/Q of the normal test current. When conducting a withstand voltage test using a parallel resonance or test transformer, the breakdown current immediately increases by several tens of times. Compared to the two, the short-circuit current and breakdown current differ by hundreds of times. Therefore, series resonance can effectively detect weak insulation points without worrying about large short-circuit current fault points.
5. There will be no overvoltage recovery. When the test sample breaks down, due to the loss of resonance conditions, the high voltage immediately disappears, the arc immediately extinguishes, and the process of restoring voltage is long, making it easy to disconnect the power supply before reaching the rated voltage. Flashing voltage again. This voltage recovery process is an intermittent oscillation process of energy accumulation. The process is long and there is no recovery overvoltage.
Wuhan UHV specializes in the production of series resonance (also known as variable frequency series resonance complete equipment) and has been engaged in the electrical measurement industry for many years. Its products have first-class quality and welcome customers to come and purchase.