Partial Discharge Test Equipment

The Best Partial Discharge Test Equipment Manufacture!

 

Wuhan UHV Power Technology Co.,Ltd.located in Wuhan East Lake New Technology Development Zone and have convenient transportation access. We are professional OEM Manufacturer which is engaged in the research, development, sale and service of High Voltage Testing Equipment including: Resonant Test System, High Voltage Tester,Transformer Tester,Circuit Beaker Tester, Relay Protection Tester, Partial Discharge Test Equipment, etc.

 
 
Why Choose Us?

Technology Certification

Obtained 6pc Computer Software Copyright Registration Certificates, 14 product patent certificates and 1 pc ISO 9001:2005 Quality Management System Certificate.

Production Capacity

Upgraded 5 products, added 4 production lines, added 2 AC resonance test system production lines, and sold a total of 3,000 sets of AC resonance test systems.

Guarantee Both Quality and Quantity

UHV implements the terms and conditions stipulated in the contract strictly, complies with product standard and multi-inspection.All products will be assembled and test strictly accord with our product process standard. All qualified products will be issued factory inspection reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.

Global Sales Market

Our products are not only selling well in mainland China, but also exported to the countries around the world including Malaysia, Indonesia, Vietnam, Philippines, Saudi Arabia, The United Arab Emirates,America, Australia, Argentina,Chile, Brazil etc.

 

 

 

Types of Partial Discharge Test Equipment

 

PD Tester

PD tester is a professional instrument used to detect partial discharge of electrical equipment. Its working principle is based on high-frequency pulse current measurement method.

Partial Discharge Tester

The partial discharge tester is a professional test instrument used to detect and analyze partial discharge phenomena inside high-voltage electrical equipment.

AC/DC Motor Test Bench

 

Technical Parameters

 

TEV measurement

UHF measurement

Measurement range

0-60 dBmV

Detection frequency band

300-2000MHz

Resolution

1dB

Measurement range

0-60 dBmV

Accuracy

±1dB

Accuracy

<1dBmV

Maximum pulse per cycle

1400

Sensor frequency band

300-2000MHz

Measurement frequency band

3~100MHz

 

 

AA measurement

AE measurement

Measurement range

-6dBμV~68dBμV

Measurement range

-6dBμV~ 68dBμV

Resolution

1dB

Resolution

1dB

Accuracy

±1dB

Accuracy

±1dB

Sensor center frequency

40 kHz

Frequency range

20~200 kHz

HFCT measurement

Sensor transmission impedance

5mV/mA

Detection frequency

1~30MHz

Sensitivity

≤50pC

Hardware

Shell

ABS

Display

4.0 inch RGB LCD Screen Resolution: 800*480

Connector

USB interface (also charger input)

3.5mm stereo earphone jack

External sensor input interface

Headset

At least 8 Ω

SD card

Standard 16G ~ 64G

Built-in battery

3.7V/5000mAh lithium battery

Working time

About 6 hours

Charger

AC 90-264V or DC 5V

Temperature

-20 ~ 50℃

Humidity

20-85% relative humidity

Dimension

210*100*35(mm) 0.4KG(host)

 

Video

 

 

 

PD Tester

Benefits of Partial Discharge Test Equipment

 

 

Early Fault Detection

Identifies insulation faults before they develop into catastrophic failures. Through early fault detections, prompt repairs are possible, which adds to the overall life of the equipment.

Predictive Maintenance

Facilitates condition-based maintenance, enhancing reliability and reducing unexpected and costly downtime.

Extended Equipment Life

Helps maintain and prolong electrical equipment’s lifespan. Reduces wear and tear caused by undetected insulation damage.

Risk Reduction and Safety Enhancement

Identifying and mitigating PD activity reduces the risk of catastrophic failures, electrical faults, and safety hazards.

Cost Savings

Minimizes repair costs and unplanned outages through early detection of potential issues.

 

Application of Partial Discharge Test Equipment
1

Power Industry

In the power industry, partial discharge test equipment is mainly used to detect the insulation status of high-voltage switchgear, ring network cabinet, voltage/current transformer, transformer (including dry-type transformer), GIS (gas insulated switchgear), overhead lines and cables.

2

Railway System

In the railway system, partial discharge test equipment is used to detect the insulation status of power equipment and signal equipment along the railway, such as traction transformers, signal power transformers, cable lines, etc.

3

Petrochemical Power Supply System

In the petrochemical power supply system, partial discharge test equipment is used to detect the insulation status of power equipment such as transformers, cable lines, motors, etc. in petrochemical enterprises.

4

Aerospace Testing Field

In the aerospace testing field, partial discharge test equipment is used to detect the insulation status of electrical equipment on aerospace vehicles, including generators, motors, cable lines, etc.

 

Tips for Selecting the Right Partial Discharge Test Equipment

Choosing the right partial discharge test equipment depends on several factors. Here are some key criteria to consider:

Measurement Range and Sensitivity

Ensure that the partial discharge test equipment covers the required measurement range and sensitivity for your applications. The measurement range can vary depending on the device type.

User-Friendliness and Interface

The device should provide an easy-to-use interface that allows for quick and simple measurements.

Frequency Analysis and Localization

If you need detailed information about the source of partial discharges, choose a device that offers frequency analysis and the ability to locate discharges.

Certifications and Standards

Ensure that the partial discharge test equipment complies with relevant safety standards and is certified for reliable and accurate measurement.

Portability and Durability

If you need to use the device on-site, ensure that it is portable and durable to provide reliable performance even in harsh conditions.

 

Partial Discharge Test Equipment Safety Tips

 

The operation and maintenance of the partial discharge tester should be carried out by competent professionals.

 
 

There should be obvious and clear warning signs in the test area, and anyone on site should be aware of the high voltage area. During the test and after power on, no one is allowed to enter the high voltage area.

 
 

Before the test, the operator should master the test circuit, test method, test procedure and test purpose.

 
 

The test site should be neat and clean, and other irrelevant items should not be stored.

 
 

The surface of the tested product, step-up transformer, coupling capacitor, etc. should be kept dry and clean, because the moisture and dirt on the surface will cause partial discharge on the surface, resulting in abnormal measurement.

 
 

The test operators connect the lines according to the requirements of the regulations. Pay special attention to whether various ground wires are well grounded.

 
 

Before the test starts to pressurize, the test personnel must check the circuit in detail and comprehensively to avoid wrong connection of the circuit.

 
 

When the test is abnormal, the power supply should be cut off first, and then further processing should be carried out.

 

 

 

Easy Online Customization

1. Please contact our online sales team via email at tina@hvtest.cc and provide the products, quantity and your customization requirements.
2. After receiving your customization requirements, our professional technicians will contact you by email to confirm your order requirements.
3. After everything is confirmed, we will send you a sample for your approval.
4. After getting your approval, we will send you a quotation for you to place an order and we will start processing your custom order.
5. After confirming and receiving 30% advance payment, we will start mass production.
6. Our technicians will control the quality during the production process.
7. According to the delivery time, we will arrange shipment after receiving the remaining payment.

PD Tester

 

Our Factory

 

If you have any requirements, pls feel free to contact us, and we will always right be here ready to serve for you.

 

20230817142714f7cf6b91330e4675ad40cfabab3d817b.jpg (1000×354)

202308171427328aac8f35affe4f86a161631453092d42.jpg (1000×462)

 

FAQ

 

Q: How long is the lead time?

A: UHV's lead time may vary depending on the model and customization requirements. Typically, standard models can be shipped quickly within 15-20 business days. For more accurate lead times, especially for customized models, please contact our sales team with your specific requirements.

Q: What are your payment terms?

A: Usually 30% deposit in advance, 70% balance against the copy of B/L. T/T, Trade Assurance, Paypal, Western Union, Credit Card, L/C, etc.

Q: What shipping options are available?

A: UHV products are typically shipped via express delivery to ensure timeliness and the integrity of the goods without damage. This shipping method is designed to provide customers with fast and secure delivery services, ensuring that you receive your products undamaged as quickly as possible. For specific shipping options, including costs and estimated delivery times, it is recommended to inquire during the purchase process or by contacting UHV customer service for detailed information.

Q: What is your after-sale service

A: We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.

Q: What’s the warranty period?

A: UHV provides one year warranty and lifetime maintenance. Free repair for mechanical failure and parts damage (no human factors and force majeure factors) under warranty (replacement parts except wearing parts are provides by UHV free of charge). Charging at reasonable cost when out of warranty.

Q: How do I choose the right equipment for my needs?

A: Choosing the right equipment depends on several factors, including the specific tests you need to perform, the range of applications you’re dealing with, and your budget. UHV offers a wide range of electrical testing equipment suitable for various applications, from protection relay testing to power quality analysis. You can consult with UHV sales engineers, who can provide expert advice based on your specific requirements and help you select the most appropriate equipment.

Q: Do you provide training on how to use the equipment?

A: Yes. UHV provides comprehensive training on how to use their equipment effectively and safely. Training can be conducted in various formats, including online tutorials, and in some cases, hands-on training sessions (subject to location and availability). This ensures that customers can maximize the potential of their UHV equipment and perform tests with confidence. For more information on training options, you can contact UHV directly.

Q: Can WUHV relay protection testers be customized?

A: Yes, UHV offers customization services to meet specific testing needs and application scenarios. If you have special requirements, please contact our sales team to discuss the possibility of customized solutions.

As one of the leading partial discharge test equipment manufacturers and suppliers in China, we warmly welcome you to buy high-grade partial discharge test equipment made in China here from our factory. For price consultation, contact us.

AC DC hipot tester

whatsapp

Phone

E-mail

Inquiry

Bag