Partial Discharge Test Equipment
The Best Partial Discharge Test Equipment Manufacture!
Wuhan UHV Power Technology Co.,Ltd.located in Wuhan East Lake New Technology Development Zone and have convenient transportation access. We are professional OEM Manufacturer which is engaged in the research, development, sale and service of High Voltage Testing Equipment including: Resonant Test System, High Voltage Tester,Transformer Tester,Circuit Beaker Tester, Relay Protection Tester, Partial Discharge Test Equipment, etc.
Why Choose Us?
Technology Certification
Obtained 6pc Computer Software Copyright Registration Certificates, 14 product patent certificates and 1 pc ISO 9001:2005 Quality Management System Certificate.
Production Capacity
Upgraded 5 products, added 4 production lines, added 2 AC resonance test system production lines, and sold a total of 3,000 sets of AC resonance test systems.
Guarantee Both Quality and Quantity
UHV implements the terms and conditions stipulated in the contract strictly, complies with product standard and multi-inspection.All products will be assembled and test strictly accord with our product process standard. All qualified products will be issued factory inspection reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.
Global Sales Market
Our products are not only selling well in mainland China, but also exported to the countries around the world including Malaysia, Indonesia, Vietnam, Philippines, Saudi Arabia, The United Arab Emirates,America, Australia, Argentina,Chile, Brazil etc.
Types of Partial Discharge Test Equipment
PD Tester
PD tester is a professional instrument used to detect partial discharge of electrical equipment. Its working principle is based on high-frequency pulse current measurement method.
Partial Discharge Tester
The partial discharge tester is a professional test instrument used to detect and analyze partial discharge phenomena inside high-voltage electrical equipment.

Technical Parameters
|
TEV measurement |
UHF measurement |
||
|
Measurement range |
0-60 dBmV |
Detection frequency band |
300-2000MHz |
|
Resolution |
1dB |
Measurement range |
0-60 dBmV |
|
Accuracy |
±1dB |
Accuracy |
<1dBmV |
|
Maximum pulse per cycle |
1400 |
Sensor frequency band |
300-2000MHz |
|
Measurement frequency band |
3~100MHz |
|
|
|
AA measurement |
AE measurement |
||
|
Measurement range |
-6dBμV~68dBμV |
Measurement range |
-6dBμV~ 68dBμV |
|
Resolution |
1dB |
Resolution |
1dB |
|
Accuracy |
±1dB |
Accuracy |
±1dB |
|
Sensor center frequency |
40 kHz |
Frequency range |
20~200 kHz |
|
HFCT measurement |
|||
|
Sensor transmission impedance |
5mV/mA |
||
|
Detection frequency |
1~30MHz |
||
|
Sensitivity |
≤50pC |
||
|
Hardware |
|||
|
Shell |
ABS |
||
|
Display |
4.0 inch RGB LCD Screen Resolution: 800*480 |
||
|
Connector |
USB interface (also charger input) 3.5mm stereo earphone jack External sensor input interface |
||
|
Headset |
At least 8 Ω |
||
|
SD card |
Standard 16G ~ 64G |
||
|
Built-in battery |
3.7V/5000mAh lithium battery |
||
|
Working time |
About 6 hours |
||
|
Charger |
AC 90-264V or DC 5V |
||
|
Temperature |
-20 ~ 50℃ |
||
|
Humidity |
20-85% relative humidity |
||
|
Dimension |
210*100*35(mm) 0.4KG(host) |
||
Video

Benefits of Partial Discharge Test Equipment
Early Fault Detection
Identifies insulation faults before they develop into catastrophic failures. Through early fault detections, prompt repairs are possible, which adds to the overall life of the equipment.
Predictive Maintenance
Facilitates condition-based maintenance, enhancing reliability and reducing unexpected and costly downtime.
Extended Equipment Life
Helps maintain and prolong electrical equipment’s lifespan. Reduces wear and tear caused by undetected insulation damage.
Risk Reduction and Safety Enhancement
Identifying and mitigating PD activity reduces the risk of catastrophic failures, electrical faults, and safety hazards.
Cost Savings
Minimizes repair costs and unplanned outages through early detection of potential issues.
Application of Partial Discharge Test Equipment
Power Industry
In the power industry, partial discharge test equipment is mainly used to detect the insulation status of high-voltage switchgear, ring network cabinet, voltage/current transformer, transformer (including dry-type transformer), GIS (gas insulated switchgear), overhead lines and cables.
Railway System
In the railway system, partial discharge test equipment is used to detect the insulation status of power equipment and signal equipment along the railway, such as traction transformers, signal power transformers, cable lines, etc.
Petrochemical Power Supply System
In the petrochemical power supply system, partial discharge test equipment is used to detect the insulation status of power equipment such as transformers, cable lines, motors, etc. in petrochemical enterprises.
Aerospace Testing Field
In the aerospace testing field, partial discharge test equipment is used to detect the insulation status of electrical equipment on aerospace vehicles, including generators, motors, cable lines, etc.
Tips for Selecting the Right Partial Discharge Test Equipment
Choosing the right partial discharge test equipment depends on several factors. Here are some key criteria to consider:
Measurement Range and Sensitivity
Ensure that the partial discharge test equipment covers the required measurement range and sensitivity for your applications. The measurement range can vary depending on the device type.
User-Friendliness and Interface
The device should provide an easy-to-use interface that allows for quick and simple measurements.
Frequency Analysis and Localization
If you need detailed information about the source of partial discharges, choose a device that offers frequency analysis and the ability to locate discharges.
Certifications and Standards
Ensure that the partial discharge test equipment complies with relevant safety standards and is certified for reliable and accurate measurement.
Portability and Durability
If you need to use the device on-site, ensure that it is portable and durable to provide reliable performance even in harsh conditions.
Partial Discharge Test Equipment Safety Tips
The operation and maintenance of the partial discharge tester should be carried out by competent professionals.
There should be obvious and clear warning signs in the test area, and anyone on site should be aware of the high voltage area. During the test and after power on, no one is allowed to enter the high voltage area.
Before the test, the operator should master the test circuit, test method, test procedure and test purpose.
The test site should be neat and clean, and other irrelevant items should not be stored.
The surface of the tested product, step-up transformer, coupling capacitor, etc. should be kept dry and clean, because the moisture and dirt on the surface will cause partial discharge on the surface, resulting in abnormal measurement.
The test operators connect the lines according to the requirements of the regulations. Pay special attention to whether various ground wires are well grounded.
Before the test starts to pressurize, the test personnel must check the circuit in detail and comprehensively to avoid wrong connection of the circuit.
When the test is abnormal, the power supply should be cut off first, and then further processing should be carried out.
1. Please contact our online sales team via email at tina@hvtest.cc and provide the products, quantity and your customization requirements.
2. After receiving your customization requirements, our professional technicians will contact you by email to confirm your order requirements.
3. After everything is confirmed, we will send you a sample for your approval.
4. After getting your approval, we will send you a quotation for you to place an order and we will start processing your custom order.
5. After confirming and receiving 30% advance payment, we will start mass production.
6. Our technicians will control the quality during the production process.
7. According to the delivery time, we will arrange shipment after receiving the remaining payment.

Our Factory
If you have any requirements, pls feel free to contact us, and we will always right be here ready to serve for you.


FAQ
As one of the leading partial discharge test equipment manufacturers and suppliers in China, we warmly welcome you to buy high-grade partial discharge test equipment made in China here from our factory. For price consultation, contact us.
AC DC hipot tester