Why does the voltage drop during the AC withstand voltage test? Wuhan UHV specializes in producing AC voltage withstand resonant devices, with a wide range of product options. When looking for AC voltage withstand resonant devices, choose Wuhan UHV.
Voltage withstand test is one of the important tests in electrical testing. Although it is a destructive test, it is also irreplaceable in terms of safety performance.
The AC voltage withstand test can be mainly divided into two types: power frequency voltage withstand test and variable frequency (AC) voltage withstand test. And they generally represent two types of testing equipment in the current market: test transformers and series resonant withstand voltage devices.
These two types of testing equipment are commonly used AC withstand voltage devices, and different devices are required for different occasions. We know that the core requirement for voltage resistance is high voltage, and we often encounter a gradual decrease in the test voltage during on-site testing. So, what are the reasons for the voltage drop?
Firstly, AC withstand voltage testing equipment belongs to transformer equipment. We all know about energy conservation, and AC withstand voltage requires electricity to be taken from the low-voltage end, that is, the 220V/380V we use is converted into high voltage through a certain transformation ratio. But we all know that the voltage on the power grid fluctuates, not a constant voltage. It is precisely because the fluctuation of low-voltage voltage causes the fluctuation of high-voltage voltage, which is one of the reasons why the AC withstand voltage test will decrease.
There is another situation that occurs more frequently. The highest voltage of the instrument we use is greater than the test voltage we need, but it cannot be raised to the required test voltage during on-site use, and this voltage drops significantly compared to the highest voltage of the instrument. If we forcefully increase the voltage, it will also cause overcurrent protection for the instrument. In fact, this does not belong to equipment failure of the instrument. Each test transformer has a certain capacity, and the capacity of the transformer determines the carrying capacity of the test transformer. If the load required for the test is greater than the capacity of the test transformer, it is very normal to cause voltage drop and overcurrent protection. At this point, we have no other way to solve this problem except by using high-capacity test transformers or other means.
Another situation is that the series resonant withstand voltage test device will experience a relatively small decrease in voltage over time when the voltage reaches the test voltage for one minute or longer to withstand voltage. This is because the series resonance withstand voltage test device adopts the LCR series resonance principle. During the withstand voltage process, due to the increase in temperature, factors such as capacitance and inductance in the LCR circuit will fluctuate, and these fluctuations will cause the voltage fluctuation of the series resonance withstand voltage test device in the end. At this point, we only need to manually apply pressure to solve this problem.
Of course, what we are talking about today is the reason for the voltage drop when the instrument is normal. If there is more help needed, you can seek the help of professional technicians.