Equivalent circuit parameters of series resonance (also known as variable frequency series resonance withstand voltage test device) circuit:
U: The output voltage of the excitation winding of the excitation transformer can be connected in series and parallel, and the frequency conversion power supply control can continuously change from 0 to Umax (Umax is the rated output voltage of the high-voltage winding of the excitation transformer after series connection). And the frequency continuously changes from 30Hz to 300Hz.
R: It is the equivalent resistance of a series resonant circuit. Including the internal resistance of the excitation transformer equivalent to the high-voltage side. The high internal resistance of high-voltage reactors, the internal resistance of samples, and the equivalent resistance of corona losses during testing.
L: It is the equivalent inductance of a series circuit. The excitation transformer is equivalent to high side leakage inductance and resonant reactor inductance. In actual testing, compared with the resonance of the resonant reactor, the leakage inductance of the excitation transformer is relatively small and can be ignored. Therefore, in rough calculations, the inductance of the reactor can be considered as the equivalent inductance of the resonant circuit. In actual testing, the reactor can have multiple series and parallel lines, and the circuit inductance in this case is the inductance of multiple reactors connected in series and parallel. When calculating the series parallel inductance of a reactor, internal resistance can be ignored and calculated based on pure inductance series parallel connection.
C: It is the sum of the load capacitance and the voltage divider capacitance of a series parallel resonant circuit. Due to the small capacitance of the voltage divider, it can be ignored in rough calculations. When the load capacitance can be compared with it, it should be included in the calculation.
The power supply is powered by a variable frequency power supply. After increasing the initial voltage through the excitation transformer, high voltage is applied to the reactor L and the test product CX. By changing the output frequency of the variable frequency power supply, it cycles in a string.
Resonant state, maintain constant frequency, adjust the output voltage of the variable frequency power supply. Make the voltage on the sample reach the desired value. The resonant frequency of the loop depends on the capacitance CX and inductance L of the test object, as well as the resonant frequency f=1/(2 π√ LC).