Insulating Boots Gloves Tester

Our company has been specializing in the production and manufacturing of frequency series resonance devices for 21 years, with a modern intelligent factory covering over 40,000 square meters and more than 100 automated production, manufacturing, assembly, and testing equipment. We have obtained CE certification and currently serve over 20,000 customers worldwide.

 

Our Insulating Boots Gloves Tester is specialized high-voltage testing equipment ,it designed to evaluate the dielectric strength and insulation integrity of insulated boots and gloves used in electrical work. This test ensures that protective equipment meets safety standards and effectively protects workers from electrical hazards.

 

Why Test Insulated Boots and Gloves?

Insulated gloves and boots provide critical protection against electric shock in high-voltage environments. Over time, insulation materials may degrade due to the following factors:

Wear and tear

Moisture exposure

Chemical contamination

Mechanical stress

Material aging

Regular testing helps detect potential faults before they compromise safety.

 

Why Choose Us?

Quotation within 1 hour – Solution within 24 hours

Product demonstration available - Strict contract performance – On-time delivery

12-month warranty – Optional extended warranty

Factory acceptance testing – Authorized calibration (optional) -

Worldwide training support – Regular follow-up visits

 

Our Product Features

1.The insulating boots gloves tester can simultaneously evaluate 8 insulated boots or gloves and measure the leakage current of each test sample.

 

2.The insulated boot test uses a dry test method, where small steel balls are placed inside instead of filling the boots with water, eliminating the drying process required in traditional testing.

 

3.High and low voltage separation: Leakage current is transmitted back to the control box using anti-interference wireless transmission technology, greatly enhancing personal safety.

 

4.Independent circuit protection: Each test sample has a dedicated breaking mechanism. If any sample breaks down or exceeds the set leakage current threshold, it will automatically detach from the test, allowing the other samples to continue testing without interruption.

 

5.Equipped with a 7-inch TFT touch screen LCD with a Chinese character display, providing real-time test data, including:

Test voltage

8-channel high-voltage leakage current

Perpetual calendar

Timing function

Test status prompts

 

6.The fully automated voltage withstand test is controlled by a DC motor-driven voltage regulator. The testing process follows national standards, with automatic:

Voltage increase at a controlled speed

Voltage holding at the target level

Countdown timer activation

Voltage reduction to zero

Power shutoff upon test completion

Automatic display and storage of leakage current data

 

7.The insulated boot test uses a dedicated stainless steel grounding tray, while the insulated glove test utilizes a dedicated stainless steel container, ensuring easy operation.

 

8.The test transformer ratio can be freely adjusted and is also compatible with the customer's existing transformer.

 

9.Overcurrent protection function ensures equipment safety.

 

21 years professional manufacturer and supplier in china, standardized factory, best product quality, and cheap wholesale prices!!!

 

Working Principle

The Insulated Boot and Glove Tester performs high-voltage AC/DC testing on gloves or boots to measure leakage current and insulation resistance.

 

Test Process

Preparation & Setup

Fill the boots or gloves with water (acting as an internal electrode).

Place them in a water-filled test tank (serving as the external electrode).

 

High-Voltage Application

Apply AC or DC high voltage (typically 5kV–50kV) to the gloves or boots.

The test voltage simulates real-life conditions to evaluate insulation integrity.

 

Leakage Current Measurement

The insulating boots gloves tester monitors the leakage current in real time.

If the leakage current exceeds the safety threshold, the test fails.

 

Analysis of Test Results

If the leakage current remains below the allowable limit, the gloves or boots pass the test.

If the current is too high, it indicates insulation breakdown or defects in the material.

 

Other Names for This Equipment

Protective Tool Insulation Test Bench

Insulation Boot & Glove Withstand Voltage Test Device

Insulation Boot & Glove Tester

Auxiliary Insulation Tool Test Device

Live Protective Equipment Insulation Test Device

Insulation Boot & Glove Test Machine

 

Product Advantages of insulating boots gloves tester
1. Multi station design: can simultaneously detect multiple gloves or shoes, improving detection efficiency;

2. Fully automatic control: automatic boosting, stabilizing, timing, and data recording, making operation easier;

3. Complete safety protection: equipped with multiple safety mechanisms such as leakage protection, short circuit protection, and overvoltage alarm;

4. Intelligent data management: supports the storage and export of experimental data, facilitating the management of enterprise experimental records.

This device is widely used in power companies, power supply bureaus, railways, chemical industries, laboratories and other units, and is an ideal choice for testing power safety tools.

 

Application Scenarios for insulating boots gloves tester

Power maintenance unit: Regularly inspect the insulation performance of insulated boots/gloves.

Tool manufacturing factory: Quality inspection before leaving the factory.

Third party testing agency: providing certification services for safety tools and equipment.

 

Precautions

Safety first: Maintain a safe distance during testing and strictly prohibit touching high-voltage parts.

Regular calibration: Regularly calibrate equipment according to regulatory requirements to ensure measurement accuracy.

Environmental requirements: Avoid use in damp and corrosive environments to prevent equipment damage.

Maintenance: Clean the contact points of the test sample after the test, and check the flexibility of the high-voltage breaking mechanism.

 

FAQ

1. What kind of experiment is this insulating boots gloves tester mainly used for
Specialized in conducting power frequency AC withstand voltage tests on high-voltage safety tools such as insulated boots, insulated gloves, and insulated shoes, to detect potential insulation layer breakdown hazards and leakage current exceeding standards, and to determine whether the tools can continue live working.

 

2. What is the core difference between fully automatic and manual pressure resistant devices, and how to choose
Manual version: manual knob boost, manual timing, single channel detection, low cost; Suitable for testing small quantities, township power supply stations, and small factories.
Fully automatic version: One click start, automatic constant voltage boost → voltage stabilization timing → automatic voltage reduction to zero, multi-channel independent monitoring of leakage current, single channel breakdown automatic tripping does not affect other test samples; Suitable for power supply companies, third-party testing agencies, and batch testing scenarios, with almost zero human error, the report can be directly used for grid acceptance.

 

3. How to choose the most suitable workstations, commonly 4, 6, and 8 workstations
4 workstations: County and district power supply bureaus, small power plants, sufficient for daily and monthly inspections.
6 workstations: mainstream standard configuration, balancing efficiency and land occupation, preferred by the vast majority of operation and maintenance units;
8 workstations: Local power supply companies, third-party testing centers, large group power plants, batch centralized annual inspections, doubling daily testing efficiency.

 

4. Why is it necessary to conduct regular pressure tests? Can equipment with intact appearance be exempted from inspection?

Absolutely not exempt from inspection. The core hidden dangers of insulation equipment are mostly internal hidden damage, material aging and decay, and unrecognizable appearance. Many insulated boots and gloves with intact appearance have significantly reduced internal insulation performance, making them prone to sudden breakdown and leakage during high-voltage operations. Only regular withstand voltage tests can accurately identify hidden dangers and ensure operational safety.

 

5. How long is the insulating boots gloves tester warranty? Can we provide on-site installation training
The whole machine comes with a standard one-year warranty and lifetime maintenance; Nationwide on-site installation, debugging, and practical training for operators.

 

21 years professional manufacturer and supplier in china, standardized factory, best product quality, and cheap wholesale prices!!!

 

As one of the leading insulating boots gloves tester manufacturers and suppliers in China, we warmly welcome you to buy high-grade insulating boots gloves tester made in China here from our factory. For price consultation, contact us.

cable withstand tester, high potential withstanding test set, hipot test interface

whatsapp

Phone

E-mail

Inquiry

Bag