Oil Flash Point Tester

Our Oil Closed Flash Point Testers use a new high-speed signal processor, a large color touch LCD display, a Chinese English human-machine dialogue interface, and are easy to operate; The instrument has functions such as automatic ignition, measurement, display and printing of test results, automatic cooling, and data storage; The characteristics include accurate measurement, good repeatability, stable and reliable performance. It can be widely used in departments such as power, petroleum, chemical, commercial inspection, and scientific research.

Product Introduction

Wuhan UHV Power Technology Co., Ltd. is a professional manufacturer of Oil Closed Flash Point Testers in China. Our closed cup flash point tester factory use a new high-speed signal processor, a large color touch LCD display, a Chinese English human-machine dialogue interface, and are easy to operate; The closed cup flash point tester has functions such as automatic ignition, measurement, display and printing of test results, automatic cooling, and data storage; The characteristics include accurate measurement, good repeatability, stable and reliable performance. It can be widely used in departments such as power, petroleum, chemical, commercial inspection, and scientific research.

 

product-3504-2336

 

Product features

 

Fully Automatic Test Process: The closed cup flash point tester supplier automatically controls heating, stirring, ignition, flash detection, and result output with a single press, eliminating manual errors and operator intervention.

Precise Temperature Control: Advanced PID technology ensures accurate heating rates and stable temperature maintenance, delivering highly repeatable flash point results. The measuring range is from room temperature to 350℃, with a platinum temperature sensor.

Atmospheric Pressure Auto-Correction: A built-in pressure sensor automatically adjusts flash point readings to standard atmospheric conditions, ensuring consistent results regardless of altitude or weather variations.

Electric Ignition with Adjustable Brightness: It uses electric ignition and features an external adjustment function for the brightness of the igniter, allowing for optimal flame detection.

Data Management: The closed cup flash point tester can store up to 1000 analysis results, has a power-down storage function, and is equipped with a thermal printer for immediate result printing. It features a color LCD display with a resistive touch screen and an English menu for convenient human-machine interaction.

Comprehensive Safety Protection: Includes over-temperature shutdown, flame-out alarm, and automatic cooling after the test to protect both the operator and the equipment.

 

Product functions

 

Automatic Flash Point Detection: Automatically detects the flash point of transformer oil, insulating oil, lubricating oil, and other compatible petroleum products using the closed-cup method.

Automatic Heating Control: Controls the heating process according to the selected test procedure to ensure consistent testing conditions.

Automatic Stirring: Provides controlled sample stirring to promote uniform temperature distribution during testing.

Automatic Ignition: Integrates an automatic ignition system to simplify operation and improve testing efficiency.

Flash Detection: Detects the flash phenomenon during the test and determines the flash point according to the applicable testing method.

Real-Time Temperature Monitoring: Monitors sample temperature throughout the testing process, allowing accurate observation of temperature changes.

Automatic Test Control: Coordinates the main testing steps to reduce manual intervention and improve operational convenience.

 

Product parameters

 

Display

Color LCD display

Operating mode

Touch Screen

Measuring range

Room temperature~350 ℃

Temperature detection

platinum

Repeatability

>110℃±2℃ ; ≤110℃±1℃

Ignition method

electric ignition

Information storage

Can store 1000 analysis results

Cooling method

Forced air cooling

Printer

Thermal printer

Repeatability

Comply with ASTM, D93, GB/T 261 standards

Power supply

alternating current 220V±11V,50Hz±2.5Hz

Power

≤350VA

Operating ambient temperature

10 ℃~35 ℃

Operating environment humidity

≤85%

 

Application field

 

1. Power Utilities & Transformer Maintenance

Tests the flash point of insulating oil used in power transformers, distribution transformers, and other equipment.

Evaluates the flammability risk of oil products during equipment commissioning, periodic maintenance, and fault repair.

Assists in identifying possible light volatile combustible contaminants in insulating oil, supporting equipment condition assessment.

2. Electrical Testing Laboratories

Performs flash point testing on transformer oil and insulating oil samples collected from the field.

Records and compares test results from different batches, different equipment, and different time periods.

Provides data support for insulating oil quality acceptance, abnormal oil sample screening, and test report preparation.

3. Petrochemical Industry & Oil Quality Control

Tests the flash point of applicable lubricating oils, fuel oils, and other petroleum products.

Used for raw material inspection, production process quality monitoring, and finished product factory testing.

Determines whether oil product flash points meet corresponding product technical specifications or procurement requirements.

4. Industrial Lubricants & Maintenance

Tests applicable lubricating oils and circulating oils used in industrial equipment.

Compares flash point changes between new oil and in-service oil to assist in identifying potential abnormalities such as light fuel contamination.

Provides reference for industrial equipment maintenance, oil replacement, and oil quality management.

5. Third-Party Inspection & Quality Assurance

Provides oil flash point testing services for power companies, petroleum companies, and industrial customers.

Conducts testing, result verification, and report preparation according to applicable testing standards.

Utilizes the device's test result storage function for historical data traceability and quality file management.

 

product-3504-2336

 

Main advantages of Oil Closed Flash Point Tester

 

1. High degree of automation
Automatically complete the entire process of heating, stirring, ignition, temperature detection, and result judgment, reducing human intervention.
Support one click start, easy to operate, reducing the technical requirements for operators.
2. High testing accuracy and good repeatability
Adopting high-precision temperature sensors and intelligent control algorithms to ensure accurate and reliable test data.
Compliant with international standards, the results are comparable and authoritative.
3. Strong security
The fully enclosed testing environment effectively prevents the leakage of volatile gases and reduces the risk of fire or explosion.
Multiple security protection mechanisms (such as over temperature alarm, automatic fire extinguishing, gas path self inspection, etc.).
4. High efficiency and time-saving
The testing cycle is short (usually a few minutes to a dozen minutes), supporting continuous multi batch testing.
Some models have automatic cleaning and cooling functions to improve throughput.
5. Convenient data management
Built in storage or computer connection, it can automatically record and export test data for easy traceability and analysis.
Support printing reports, electronic signatures, and other functions to meet the requirements of laboratory informationization.

 

product-3504-2336

 

Why choose us as the supplier of Oil Closed Flash Point Testers?

 

Our fully automatic closed flash point tester is designed specifically for transformer oil analysis in the power industry. It features high precision, intelligent automation, stable operation, and long-term reliability, and is widely used in laboratory and on-site testing applications.

product-625-411
product-627-414
product-627-423

 

 

 

FAQs

 

1. What is an Oil Flash Point Tester used for?

An Oil Flash Point Tester is used to determine the flash point of insulating oil, transformer oil, lubricating oil, fuel oil, and other petroleum products. It helps evaluate oil safety, identify potential contamination or deterioration, and ensure compliance with relevant testing standards.

2. Why is flash point testing important for transformer oil?

Flash point testing helps assess the fire safety characteristics of transformer oil. A significant decrease in flash point may indicate contamination with volatile substances or other abnormal changes in oil quality. Regular testing supports transformer maintenance and helps identify potential safety risks.

3. What is the difference between flash point and fire point? The flash point is the lowest temperature at which a liquid produces enough vapor to ignite momentarily under specified test conditions. The fire point is the temperature at which the vapor continues to burn for a specified period. These two values are different and should not be used interchangeably.

4.How can I improve the repeatability of flash point measurements? ,Use representative samples, clean the test cup, follow the prescribed sample volume, maintain the specified heating procedure, and verify the instrument regularly. Consistent sample handling and compliance with the relevant test standard are essential for repeatable results.

How can I improve the repeatability of flash point measurements?

5.Use representative samples, clean the test cup, follow the prescribed sample volume, maintain the specified heating procedure, and verify the instrument regularly. Consistent sample handling and compliance with the relevant test standard are essential for repeatable results.

 

Our export experience is extensive

 

We have extensive export experience in power testing equipment and have supplied products to customers in Asia, Europe, the Middle East, Africa, and South America. Our team is familiar with international standards, export procedures, and overseas technical support requirements.

 

2

5-6

 

Precautions for Oil Closed Flash Point Tester

 

1. During the testing process, users should be careful to avoid burning their hands;

2. After testing a sample, wait for the instrument to cool down for 20 minutes before starting a new testing process;

3. The closed cup flash point tester should be placed in a location with low air flow (such as a fume hood) to prevent external airflow from dispersing smoke and interfering with test results;

4. When replacing the test sample, the oil cup needs to be rinsed with the sample;

5. When the instrument malfunctions, the power should be cut off immediately. After the instrument cools down, professional personnel should be hired to repair and eliminate the fault before continuing to use it to avoid accidents.

 

Maintenance and Care

 

1. The closed cup flash point tester should be used in a non corrosive environment.

2. The closed cup flash point tester should be stored at 10-50 ℃ with a relative humidity below 85%;

3. If the closed cup flash point tester is not used for a long time, it should also be turned on regularly. Long term shutdown can accumulate dust and moisture, which may cause abnormal operation when restarted. It is recommended to turn it on at least once every two weeks for 2 hours each time.

 

Production workshop of Oil Closed Flash Point Tester

 

Our Oil Closed Flash Point Tester production workshop is designed strictly in accordance with precision instrument manufacturing standards, with an independent anti-static clean assembly area and a constant temperature and humidity calibration room. Key processes such as temperature sensor coupling and ignition circuit withstand voltage testing are subject to online control. Before leaving the factory, each instrument uses three or more national standard oil samples for full range calibration. The workshop environment is clean and bright, with constant temperature and humidity throughout the year, allowing you to purchase with peace of mind and use with confidence.

 

Our oil flash point testing equipment is designed to deliver consistent test results, convenient operation, and efficient performance for laboratories and industrial applications. If you are comparing Oil Flash Point Tester prices or looking for a trusted supplier for your business, UHV is ready to support your needs with detailed product information and competitive quotations. Contact us to learn more about our products and find the right testing solution for your requirements.

 

product-625-411

 

Hot Tags: oil flash point tester, China oil flash point tester manufacturers, suppliers, factory, Transformer oil gas content test device, Transformer oil analysis machine, dga in transformer oil, Six cup BDV tester, Oil electrical properties tester, Transformer insulating oil BDV measurement tool

Send Inquiry

You Might Also Like

    whatsapp

    Phone

    E-mail

    Inquiry

    Bag