UHV-220/30FK Battery Discharge Tester
After years of research and development, our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge meter can be in offline mode, battery as discharge load, Through continuously regulating discharge current, constant discharge current at the set value can be realized. When discharging, the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit, or the set discharge time or the set discharge capacity, and record all valuable and continuous real-time process data.
Battery discharge meter system the voltage monitoring information of single battery is simple, safe and accurate with wireless relay access.
Battery discharge meter manufacturer has a very friendly man-machine interface, which can not only complete all kinds of settings and data query under the prompt of menu, but also save the process data of discharge in the memory of the equipment, transfer to the U disk through the data interface, and analyze the data through the special software of the upper computer to generate the required curve and report.
Battery discharge tester there is perfect protection function, not only sound, light warning, but also a clear interface tips.

Product Characteristics
1,10 ~ 600V wide voltage design, single machine can meet a variety of voltage grade battery discharge test,voltage continuously adjustable.
2,Constant current discharge function, current continuously adjustable, accurate measure battery capacity.
3,With the wireless monitoring function of monomer voltage, each wireless monitoring module can monitor 12 monomers at the same time.
4,With Chinese background analysis software, with remote control discharge function.
5,The host is equipped with USB interface and 2G super capacity internal data storage space.
6,Double cpus work together to ensure the safety, reliability and accuracy of the test.

Product Parameters
Technical Parameters
|
Applicable battery |
24V,48V,72V,96V,110V,220V,240V,380V,480V |
|||
|
Working mode |
can be used alone, can be used simultaneously, can be remote control and status monitoring |
|||
|
Discharge voltage |
DC 10V~300V |
DC 10V~600V |
||
|
Discharge current |
10~19V:0~50A; 19~180V:0~100A; 180~300V:0~50A; |
10~19V:0~80A; 19~180V:0~120A; 180~300V:0~80A; |
10~19V:80A; 19~180V:120A; 180~300V:80A; 300~600V:50A; |
10~19V:150A; 19~180V:300A; 180~300V:150A; 300~600V:60A; |
|
Accuracy of current |
1% |
|||
|
Voltage accuracy |
0.5% |
|||
|
Monomer voltage accuracy |
0.2% |
|||
|
Monomer voltage |
0.500V~16.00V(resolution 1mv) |
|||
|
Charge discharge time |
0 ~ 99 hours and 59 minutes |
|||
|
Power supply |
AC:220V |
|||
|
Cooling way |
forced air cooling |
|||
|
Packaging |
aluminum alloy pull box |
|||
Technical Parameters
Work Environment
|
Heat dissipation |
forced air cooling |
|
Temperature |
working range: -5 ~ 50℃ storage temperature: -40 ~ 70℃ |
|
Humidity |
relative to humidity0 ~ 90% (40±2℃) |
|
Altitude |
rated altitude: 4000 m |
|
Noise |
﹤60dB |
Working Power Supply
|
Voltage |
single-phase three-wire system: 220V AC (- 20% ~ +30%), frequency :45 ~ 65Hz |
|
Withstand voltage test |
input - housing: 2200V DC 1min |
|
input-output: 2200V DC 1min |
|
|
output - housing: 700V DC 1min |
|
|
Security |
meet EN610950 |
Wiring
|
AC input |
Gb socket, suitable for 1 ~ 1.5mm2cable |
|
DC output |
instrument 25 mm2Cable quick connect plug (red positive black negative) |
Application Scenarios
1. Substations
Used for capacity and discharge testing of battery banks in DC systems, measuring actual battery capacity, discharge time, and individual cell voltage, promptly identifying capacity degradation or abnormal batteries.
2. Power Plants
Used for performance testing and maintenance of batteries in power plant DC systems, verifying whether battery banks meet the power supply requirements for control, protection, and emergency backup power.
3. Communication Base Stations
Mainly used for testing 48V communication battery banks, measuring actual capacity and backup power supply capability, helping operation and maintenance personnel promptly identify aging or degraded batteries.
4. Communication Rooms
Used for capacity and discharge performance testing of backup batteries in communication rooms, ensuring that batteries can provide reliable backup power for communication equipment during mains power interruptions.
5. Data Centers
Used for capacity testing and performance evaluation of UPS battery banks in data centers, verifying actual backup power supply capability, reducing power supply risks caused by insufficient battery capacity.
6. UPS Systems
Used for periodic discharge and capacity testing of UPS battery banks, detecting battery performance through actual discharge, and determining whether batteries require maintenance or replacement.
7. Energy Storage Systems
Used for discharge performance and capacity testing of energy storage battery banks or clusters, providing test data for installation commissioning, operation and maintenance, and performance evaluation of energy storage systems.
8. Industrial Backup Power
Applicable to backup battery testing in industrial scenarios such as petrochemical, mining, and manufacturing, ensuring that critical equipment and control systems have reliable backup power supply capability during power outages.
FAQS
Q1:What is the main function of the battery discharge tester?
A1:The battery discharge tester is designed to perform controlled battery discharge testing, evaluate battery capacity, monitor battery health, and analyze overall battery performance through constant-current discharge.
Q2:What types of batteries can this tester be used for?
A2:The tester is commonly used for: Lead-acid batteries Lithium battery systems UPS backup batteries Telecom batteries Power station battery banks Industrial energy storage systems.
Q3:Does the tester support constant-current discharge?
A3:Yes. The instrument continuously regulates the discharge current to maintain a stable preset current value throughout the test process.
Q4:Is the tester suitable for preventive maintenance?
A4:Absolutely. Regular discharge testing is one of the most effective methods for preventive battery maintenance and reliability assessment.
Wuhan UHV Power Technology Co.,Ltd., is a professional manufacturer and supplier of high-voltage power testing equipment in China.We have our own factory with over 10 years of production experience,and we can provide the best professional Battery Charge and Discharge Tester for sales and competitive price.We offer free consulting service, one year warranty, and adopt various methods such as email communication, video calls, aiming to solve any after-sales problems in a timely manner.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Hot Tags: battery discharge capacity tester, China battery discharge capacity tester manufacturers, suppliers, factory, heavy duty battery discharge tester, battery test equipment for telecom operators, battery discharge tester for emergency backup batteries, battery discharge capacity test requirements industrial, battery test kit for critical infrastructure batteries, battery performance capacity tester