video
Transformer Dielectric Loss Tester

Transformer Dielectric Loss Tester

The UHV-342 Transformer Dielectric loss tester is used for on-site anti-interference dielectric loss measurement or laboratory precision dielectric loss measurement.

Product Introduction

Product introduction

 

The transformer dielectric loss tester is an instrument used to measure the dielectric loss factor (tan δ) and capacitance of the transformer insulation system. It can evaluate the performance of the transformer based on these data and detect whether it has problems such as aging, moisture or insulation defects.

 

Product features

High-precision Measurement
For tanδ measurement, the transformer dielectric loss tester has an accuracy of ±1.5%, while the capacitance measurement accuracy is ±1.5%. Compared with the common products on the market with a tanδ measurement accuracy of ±2% and a capacitance measurement accuracy of ±2%~3%, this tester has an accuracy improvement of about 25%, and can more accurately capture small changes in dielectric loss.

1002

Wide Measurement Range
The transformer dielectric loss tester has a tanδ measurement range from 0.01% to 100%, while the capacitance measurement range can reach 3PF to 60000PF (at 10kV) or 30000PF (at 5kV) at different voltage levels. Usually other products have a capacitance measurement range of only 10PF to 10000PF. This means that using one of our devices can meet the test requirements of transformers with different capacitance values.

 

Multi-level High-voltage Output
The transformer dielectric loss tester is equipped with a high-voltage output capability from 0.5kV to 10kV, with a step of 500V, and a total of 20 voltage levels. In comparison, general products on the market can only provide 10-15 voltage levels. Multi-level high-voltage output allows testers to more accurately select the most appropriate test voltage according to the rated voltage and test requirements of different transformers.

 

 

Technical parameters

 

High voltage output

0.5~10kV

Increasing by 500V for each level, a total of 20 levels,capacity:1500VA

Accuracy

tgδ: ± (reading*1.5%+0.06%)

Cx: ± (reading*1.5%+5 PF)

Resolution

tgδ: 0.01%

Cx: 1pF

Measuring range

0.01%< tgδ <100%

3PF< Cx <60000PF

When it is 10kV,Cx ≤ 30000PF

When it is 5kV,Cx ≤ 60000PF

Power supply

AC 220V ± 10% ,50 ± 1Hz

Measuring method

Working frequency: 50Hz

Different frequency: 45Hz/55Hz Automatic frequency conversion

Harmonic adaptation

≤ 3%

Application condition

-15℃-50℃ Relative humidity <80%

Dimension

460 (L) × 345 (W) × 350 (H)

Weight

35 kg

 

product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600
product-800-600

 

Hot Tags: transformer dielectric loss tester, China transformer dielectric loss tester manufacturers, suppliers, factory

Send Inquiry

You Might Also Like

whatsapp

Phone

E-mail

Inquiry

Bag