video
Vacuum Circuit Breaker Analyser

Vacuum Circuit Breaker Analyser

A Vacuum Circuit Breaker Analyser is a specialized electrical testing instrument designed to measure and evaluate whether the internal vacuum level of a vacuum switch (primarily the vacuum interrupter) meets required standards.

Product Introduction

 

Product introduction

The Vacuum Circuit Breaker Analyser is an indispensable key device for power system maintenance. Using specific physical methods (primarily the magnetic control discharge method or capacitive coupling method), it quickly, accurately, and non-destructively detects the internal vacuum level of the vacuum interrupter. This determines whether the core component of the vacuum switch is healthy and capable of reliably interrupting current and maintaining insulation. Conducting regular vacuum level tests is a crucial measure to ensure the safe and stable operation of electrical equipment.

38502

Technical Parameters

 

Test object Various types of vacuum switch tubes
Test method Non-disassembly measurement of vacuum tubes using a new excitation coil
Scope of application This instrument is a multi-purpose machine, which can measure various types of vacuum switches.
Measuring range 10-5~10-1 Pa
measurement accuracy 10-5~10-4 Pa,10%
10-4~10-3 Pa,10%
10-3~10-2 Pa,10%
10-2~10-1 Pa,10%
Magnetic field voltage 1700V
Pulsed electric field high voltage 30kV
Switch tube opening distance when testing

vacuum

Normal use of open distance
Use environment -20℃~40℃
Host weight 24kg
Dimensions 410×320×370mm3
Sampler Magnetron coil

 

Core Purpose

271

1.Ensure Safe and Reliable Operation: Vacuum switches rely on a high-vacuum environment inside the interrupter (typically below 10⁻⁴ Pa) to extinguish electric arcs. If the vacuum degrades (i.e., internal pressure rises), its insulation and arc-quenching performance drop sharply, potentially causing switching failures, restrikes, or even explosions, seriously threatening power system safety.

2.Preventive Maintenance: Vacuum levels can gradually decrease over time due to seal degradation or material outgassing. Regular testing identifies hidden issues before failures occur, preventing equipment damage and power outages.

3.Fault Diagnosis: When a switch malfunctions (e.g., fails a withstand voltage test, exhibits abnormal switching), measuring vacuum level is a key diagnostic step.

4.Acceptance Inspection: Newly installed switches or those with replaced interrupters require vacuum testing to confirm their initial condition is qualified.

Testing Principles (Common Methods)

 

1.Magnetic Control Discharge Method (Mainstream):

Apply a high DC voltage between the moving and fixed contacts inside the interrupter.

Simultaneously apply a pulsed strong magnetic field to the interrupter's external shield (or a specially designed excitation coil).

Under the strong magnetic field, residual gas molecules inside the interrupter become ionized, forming a rotating electron flow.

This ionized electron flow collides with gas molecules, generating an ion current.

Measure the magnitude of this ion current. Within a certain range, the ion current is linearly proportional to the internal gas pressure (the inverse of vacuum level).

The instrument converts the measured ion current value into the corresponding vacuum level (Pa or Torr) using calibrated curves or algorithms.

2.Capacitive Coupling Method / Phase-Shift Method:

Utilizes the two series capacitors formed by the moving contact-shield and shield-fixed contact within the vacuum interrupter.

Apply an AC high voltage (typically power frequency or higher) to the interrupter.

Measure the leakage current flowing through these series capacitors (or measure the shield potential).

The leakage current magnitude is closely related to the interrupter's internal vacuum level (gas pressure). Higher vacuum means smaller leakage current; degraded vacuum (higher pressure) causes a significant increase in leakage current.

The instrument measures this current (or related parameters) and converts it into vacuum level.

3.Other Methods: Include pulse magnetic method, photoelectric method, etc., though these are less common than the two above.

 

 

Our Vacuum Circuit Breaker Analyser provides accurate, non-destructive vacuum level measurement for vacuum interrupters, helping ensure the safety and reliability of power systems. If you are looking for a competitive vacuum circuit breaker analyser price, we welcome you to contact us for the latest quotation, product specifications, and customized solutions to meet your testing requirements. Our team is ready to provide professional technical support and help you find the right testing equipment for your application.

product-2000-1501
product-2000-1188
product-2000-1500
product-2000-1296
product-2000-1500
product-2000-1500
product-1971-1478
product-2000-1501
product-2000-1500
product-1960-1470

Hot Tags: vacuum circuit breaker analyser, China vacuum circuit breaker analyser manufacturers, suppliers, factory, breaker contact resistance trending system, CB analyzer for condition monitoring services, breaker vacuum interrupter contact analysis, breaker contact resistance field tester, CB analyzer with real time monitoring, CB analyzer for transformer substations

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag